ZHCSHP4B December 2018 – October 2019 TPS7A26
PRODUCTION DATA.
請參考 PDF 數據表獲取器件具體的封裝圖。
The Device Functional Mode Comparison table shows the conditions that lead to the different modes of operation. See the Electrical Characteristics table for parameter values.
| OPERATING MODE | PARAMETER | |||
|---|---|---|---|---|
| VIN | VEN | IOUT | TJ | |
| Normal operation | VIN > VOUT(nom) + VDO and VIN > VIN(min) | VEN > VEN(HI) | IOUT < IOUT(max) | TJ < TSD(shutdown) |
| Dropout operation | VIN(min) < VIN < VOUT(nom) + VDO | VEN > VEN(HI) | IOUT < IOUT(max) | TJ < TSD(shutdown) |
| Disabled
(any true condition disables the device) |
VIN < VUVLO | VEN < VEN(LOW) | Not applicable | TJ > TSD(shutdown) |