ZHCSQN1A October 2023 – December 2024 TPS1210-Q1
PRODUCTION DATA
| 參數 | 測試條件 | 最小值 | 典型值 | 最大值 | 單位 | |
|---|---|---|---|---|---|---|
| 電源電壓 | ||||||
| VS | 工作輸入電壓 | 3.5 | 40 | V | ||
| V(S_PORR) | 輸入電源 POR 閾值,上升 | 1.85 | 2.55 | 3.3 | V | |
| V(S_PORF) | 輸入電源 POR 閾值,下降 | 1.71 | 2.33 | 3.05 | V | |
| I(Q) | 系統總靜態電流,I(GND) | V(EN/UVLO) = 2V | 35 | 45 | μA | |
| 系統總靜態電流,I(GND) | V(EN/UVLO) = 2 V,–40°C ≤ TJ ≤ +85°C | 44 | μA | |||
| I(SHDN) | SHDN 電流,I(GND) | V(EN/UVLO) = 0V,V(SRC) = 0V | 0.86 | 3.3 | μA | |
| I(REV) | 反極性期間的漏電流,I(VS) | V(VS) = –40V | 11 | 13 | 23 | μA |
| 使能、欠壓鎖定 (EN/UVLO)、短路比較器測試 (SCP_TEST) 輸入 | ||||||
| V(UVLOR) | UVLO 閾值電壓,上升 | 1.176 | 1.23 | 1.287 | V | |
| V(UVLOF) | UVLO 閾值電壓,下降 | 1.09 | 1.138 | 1.184 | V | |
| V(ENR) | 低 Iq 關斷使能閾值電壓,上升 | 1 | V | |||
| V(ENF) | 低 Iq 關斷使能閾值電壓,下降 | 0.3 | V | |||
| I(EN/UVLO) | 使能輸入漏電流 | V(EN/UVLO) = 12V | 170 | 310 | nA | |
| V(SCP_TEST_H) | SCP 測試模式上升閾值 | 2 | V | |||
| V(SCP_TEST_L) | SCP 測試模式下降閾值 | 0.8 | V | |||
| I(SCP_TEST) | SCP_TEST 輸入漏電流 | 90 | 700 | nA | ||
| 電荷泵 (BST-SRC) | ||||||
| I(BST) | 電荷泵電源電流 | V(BST – SRC) = 10V,V(EN/UVLO) = 2V | 190 | 345 | 466 | μA |
| V(BST_UVLOR) | V(BST – SRC) UVLO 電壓閾值,上升 | V(EN/UVLO) = 2V | 8.1 | 9 | 9.9 | V |
| V(BST_UVLOF) | V(BST – SRC) UVLO 電壓閾值,下降 | V(EN/UVLO) = 2V | 7.31 | 8.2 | 8.9 | V |
| V(BST–SRC_ON) | 電荷泵導通電壓 | V(EN/UVLO) = 2V | 9.3 | 10.3 | 11.4 | V |
| V(BST–SRC_OFF) | 電荷泵關斷電壓 | V(EN/UVLO) = 2V | 10.4 | 11.6 | 12.8 | V |
| V(BST–SRC) | V(VS) = 3.5V 時的電荷泵電壓 | V(EN/UVLO) = 2V | 9.1 | 10.5 | 11.6 | V |
| I(SRC) | SRC 引腳漏電流 | V(EN/UVLO) = 2V,V(INP1) = V(INP2) = 0V | 0.4 | μA | ||
| 柵極驅動器輸出(G1PU、G1PD、G2) | ||||||
| V(G1_GOOD) | G1 正常上升閾值 | 5.5 | 7 | 8.3 | V | |
| I(G1PU) | 峰值拉電流 | 1.69 | A | |||
| I(G1PD) | 峰值灌電流 | 2 | A | |||
| I(G2) | G2 峰值拉電流 | 1.69 | A | |||
| I(G2) | G2 峰值灌電流 | 2 | A | |||
| 短路保護 (ISCP) | ||||||
| ISCP | SCP 輸入偏置電流 | 8.4 | 10 | 12.33 | μA | |
| V(SCP) | SCP 閾值 | R(ISCP) = 140.5 k? | 300 | mV | ||
| R(ISCP) = 28 k? | 60 | 75 | 90.5 | mV | ||
| R(ISCP) = 10.5 k? | 32 | 40 | 48.9 | mV | ||
| R(ISCP) = 500 ? | 15 | 20 | 25 | mV | ||
| R(ISCP) = 開路 | 757 | mV | ||||
| V(SCP) | ISCP 引腳上具有外部偏置電壓時的 SCP 閾值 | V(ISCP) = 1.405 V | 283 | 300 | 316 | mV |
| V(ISCP) = 280 mV | 68.7 | 75 | 82.5 | mV | ||
| V(ISCP) = 105 mV | 34.5 | 40 | 46.5 | mV | ||
| 延遲計時器(TMR) | ||||||
| I(TMR_SRC_CB) | TMR 源電流 | 67 | 87 | 104 | μA | |
| I(TMR_SRC_FLT) | TMR 源電流 | 1.4 | 2.73 | 3.8 | μA | |
| I(TMR_SNK) | TMR 灌電流 | 2.17 | 2.8 | 3.4 | μA | |
| V(TMR_SC) | 0.93 | 1.1 | 1.2 | V | ||
| V(TMR_LOW) | 0.15 | 0.21 | 0.25 | V | ||
| N(A-R Count) | 32 | |||||
| 輸入控制(INP1、INP2)、電流檢測選擇 (CS_SEL) 和故障標志 (FLT) | ||||||
| R(FLT) | FLT 下拉電阻 | 53 | 83 | 107 | ? | |
| I(FLT) | FLT 輸入漏電流 | 0V ≤ V(FLT) ≤ 20V | 410 | nA | ||
| V(INP1_H)、V(INP2_H) | 2 | V | ||||
| V(INP1_L)、V(INP2_L) | 0.8 | V | ||||
| I(INP1)、I(INP2) | INP 輸入漏電流 | 98 | 206 | nA | ||
| V(CS_SEL_H) | 用于低檢測的 CS_SEL 閾值 | 2 | V | |||