ZHCSXX7A February 2025 – April 2025 TMUX8612
PRODUCTION DATA
| 參數 | 測試條件 | TA | 最小值 | 典型值 | 最大值 | 單位 | |
|---|---|---|---|---|---|---|---|
| 模擬開關 | |||||||
| RON | 導通電阻 | VS = -10V 至 +10V ID = -10mA |
25°C | 14 | 19.6 | Ω | |
| -40°C 至 +50°C | 21 | ||||||
| -40°C 至 +85°C | 22.4 | ||||||
| -40°C 至 +125°C | 28 | ||||||
| ΔRON | 通道間的導通電阻不匹配 | VS = -10V 至 +10V ID = -10mA |
25°C | 0.28 | 0.84 | Ω | |
| -40°C 至 +50°C | 1 | ||||||
| -40°C 至 +85°C | 1.12 | ||||||
| -40°C 至 +125°C | 1.4 | ||||||
| RON FLAT | 導通電阻平坦度 | VS = -10V 至 +10V ID = -10mA |
25°C | 0.25 | Ω | ||
| RON DRIFT | 導通電阻漂移 | VS = 0V,IS = –10mA | -40°C 至 +125°C | 0.08 | ?/°C | ||
| IS(OFF) | 源極關斷漏電流(1) | VDD = 16.5 V,VSS = -16.5 V 開關狀態為關斷 VS = +10 V/-10 V VD = -10 V/+10 V |
25°C | 12 | 100 | pA | |
| -40°C 至 +50°C | -270 | 70 | 270 | ||||
| -40°C 至 +85°C | -1250 | 1250 | |||||
| -40°C 至 +125°C | -13000 | 13000 | |||||
| ID(OFF) | 漏極關斷漏電流(1) | VDD = 16.5 V,VSS = -16.5 V 開關狀態為關斷 VS = +10 V/-10 V VD = -10 V/+10 V |
25°C | 12 | 100 | pA | |
| -40°C 至 +50°C | -270 | 70 | 270 | ||||
| -40°C 至 +85°C | -1250 | 1250 | |||||
| -40°C 至 +125°C | -13000 | 13000 | |||||
| IS(ON) ID(ON) |
通道導通漏電流(2) | VDD = 16.5V,VSS = -16.5V 開關狀態為導通 VS = VD = ±10V |
25°C | 45 | 150 | pA | |
| -40°C 至 +50°C | -270 | 270 | |||||
| -40°C 至 +85°C | -800 | 800 | |||||
| -40°C 至 +125°C | -6500 | 6500 | |||||
| ΔIS(ON) ΔID(ON) |
通道之間的漏電流不匹配(2) | VDD = 16.5V,VSS = -16.5V 開關狀態為導通 VS = VD = ±10V |
25°C | 20 | pA | ||
| 50°C | 25 | ||||||
| 85°C | 30 | ||||||
| 125°C | 110 | ||||||