ZHCSWM8A June 2024 – December 2024 TCAN1472-Q1
PRODUCTION DATA
| 參數(shù) | 測(cè)試條件 | 最小值 | 典型值 | 最大值 | 單位 | ||
|---|---|---|---|---|---|---|---|
| ICC | 電源電流,正常模式 |
顯性 | TXD = 0V,STB = 0V RL = 60Ω,CL = 開路 請(qǐng)參閱圖 6-1 |
50 | 70 | mA | |
| 顯性 | TXD = 0V,STB = 0V RL = 50Ω,CL = 開路 請(qǐng)參閱圖 6-1 |
55 | 80 | mA | |||
| 隱性 | TXD = VIO,STB = 0V RL = 50Ω,CL = 開路 請(qǐng)參閱圖 6-1 |
7 | 11 | mA | |||
| 顯性,存在總線故障 | TXD = 0V,STB = 0V CANH = CANL = ±25V RL = 開路,CL = 開路 請(qǐng)參閱圖 6-1 |
130 | mA | ||||
| 電源電流待機(jī)模式(有 VIO 的器件) | TXD = STB = VIO,RL = 50Ω,CL = 開路,Tj <= 85°C,請(qǐng)參閱圖 6-1 | 1 | μA | ||||
| TXD = STB = VIO,RL = 50Ω,CL = 開路,Tj <= 125°C,請(qǐng)參閱圖 6-1 | 0.2 | 2 | |||||
| TXD = STB = VIO,RL = 50Ω,CL = 開路,Tj <= 150°C,請(qǐng)參閱圖 6-1 | 5 | ||||||
| 電源電流待機(jī)模式(無 VIO 的器件) | TXD = STB = VCC,RL = 50Ω,CL = 開路,Tj <= 85°C,請(qǐng)參閱圖 6-1 | 15 | |||||
| TXD = STB = VCC,RL = 50Ω,CL = 開路,Tj <= 125°C,請(qǐng)參閱圖 6-1 | 16 | μA | |||||
| TXD = STB = VCC,RL = 50Ω,CL = 開路,Tj <= 150°C,請(qǐng)參閱圖 6-1 | 21 | ||||||
| IIO 有 VIO 的器件 |
I/O 電源電流,正常模式 |
顯性 | TXD = 0V,STB = 0V RL = 60Ω,CL = 開路 RXD 懸空 |
125 | 300 | μA | |
| 隱性 | TXD = VIO,STB = 0V RL = 60Ω,CL = 開路 RXD 懸空 |
25 | 48 | μA | |||
| I/O 電源電流,待機(jī)模式 | TXD = VIO,STB = VIO RL = 60Ω,CL = 開路 RXD 懸空,Tj <= 85°C |
13.5 | μA | ||||
| TXD = VIO,STB = VIO RL = 60Ω,CL = 開路 RXD 懸空,Tj <= 125°C |
8.5 | 15 | |||||
| TXD = VIO,STB = VIO RL = 60Ω,CL = 開路 RXD 懸空,Tj <= 150°C |
16 | ||||||
| UVCC(R) | VCC 上升時(shí)的欠壓檢測(cè) | 斜升 | 4.2 | 4.4 | V | ||
| UVCC(F) | VCC 下降時(shí)的欠壓檢測(cè) | 斜降 | 3.5 | 4 | V | ||
| UVIO(R) | VIO 上升時(shí)的欠壓檢測(cè)(有 VIO 的器件) | 斜升 | 1.6 | 1.65 | V | ||
| UVIO(F) | VIO 下降時(shí)的欠壓檢測(cè)(有 VIO 的器件) | 斜降 | 1.4 | 1.5 | V | ||