ZHCSIU0E February 2000 – March 2025 LM4051-N
PRODUCTION DATA
| 參數 | 測試條件 | 最小值 | 典型值 | 最大值 | 單位 | |||
|---|---|---|---|---|---|---|---|---|
| VR | 反向擊穿電壓 | IR = 100μA | 1.225 | V | ||||
| 反向擊穿電壓容差 (2) | IR = 100μA | LM4051AIM3(1) | ±1.2 | mV | ||||
| LM4051BIM3 LM4051BEM3(1) | ±2.4 | |||||||
| LM4051CIM3(1) | ±6 | |||||||
| 工業溫度范圍 TA = TJ = TMIN 至 TMAX | LM4051AIM3(1) | ±5.2(2) | ||||||
| LM4051BIM3 (1) | ±6.4(2) | |||||||
| LM4051CIM3(1) | ±10.1(2) | |||||||
| 擴展溫度:范圍 TA = TJ = TMIN 至 TMAX | LM4051BEM3(1) | ±8.6(2) | ||||||
| IRMIN | 最小工作電流 | TJ = 25°C | 39 | μA | ||||
| 工業溫度范圍 TA = TJ = TMIN 至 TMAX | 65 | |||||||
| 擴展溫度:范圍 TA = TJ = TMIN 至 TMAX | 70 | |||||||
| ?VR/?T | 平均反向擊穿電壓溫度系數(2) | IR =10mA | ±20 | ppm/ ?℃ | ||||
| IR =1mA | ±15 | |||||||
| IR = 100μA ?T = ?40?℃ 至 125℃ | TJ = 25°C | ±15 | ||||||
| TA = TJ = TMIN 至 TMAX | ±50(2) | |||||||
| ?VR/?IR | 隨著工作電流的變化,反向擊穿電壓會發生變化 | IRMIN ≤ IR ≤ 1mA | TJ = 25°C | 0.3 | mV | |||
| 工業溫度范圍 TA = TJ = TMIN 至 TMAX | 1.1(2) | |||||||
| 擴展溫度:范圍 TA = TJ = TMIN 至 TMAX | 1.5(2) | |||||||
| 1mA ≤ IR ≤ 12mA | TJ = 25°C | 1.8 | ||||||
| 工業溫度范圍 TA = TJ = TMIN 至 TMAX | 6(2) | |||||||
| 擴展溫度:范圍 TA = TJ = TMIN 至 TMAX | 8(2) | |||||||
| ZR | 反向動態阻抗 | IR = 1mA,f = 120Hz | 0.5 | Ω | ||||
| eN | 寬帶噪聲 | IR = 100μA 10Hz ≤ f ≤ 10kHz | 20 | μVrms | ||||
| ?VR | 反向擊穿電壓的長期穩定性(3) | t = 1000hrs,T = 25℃ ± 0.1℃,IR = 100μA | 120 | ppm | ||||
| VHYST | 熱磁滯(4) | ?T = ?40℃ 至 125?℃ | 0.36 | mV/V | ||||