VALUE |
UNIT |
| V(ESD)
|
Electrostatic discharge |
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
|
±3000 |
V |
| Charged device model (CDM), per JEDEC specification JESD22-C101(2)
|
±500 |
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. Pins listed as ±3 kV may actually have higher performance.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.