over operating free-air temperature range (unless
otherwise noted) (1)
|
MIN |
MAX |
UNIT |
| VCC |
Supply
voltage range |
|
?0.5 |
6 |
V |
| IIK |
Input clamp
current |
(VI
< 0 or VI > VCC) 1 |
|
±20 |
mA |
| IOK |
Output clamp
current |
(VO < 0 or VO > VCC)
1 |
|
±50 |
mA |
|
Continuous
output current |
(VO = 0 to VCC) |
|
±50 |
mA |
|
Continuous current through VCCor GND |
|
±100 |
mA |
| Tstg |
Storage temperature range |
?65 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum
Ratings may cause permanent damage to the device. These are stress
ratings only, which do not imply functional operation of the device at these or
any other conditions beyond those indicated under Recommended Operating
Conditions. Exposure to absolute-maximum-rated conditions for extended
periods may affect device reliability.