| EN |
2 |
I |
Enable and shut down |
| FAULT |
6 |
I/O |
Fault pin. Leave floating if not used. |
| FAULT_S |
7 |
I/O |
Single-LED short fault. Leave floating if not used. |
| GND |
10 |
— |
Ground |
| IOUT1 |
16 |
O |
Current output pin. Connect to VSNS1 if not used. |
| IOUT2 |
15 |
O |
Current output pin. Connect to VSNS2 if not used. |
| IOUT3 |
14 |
O |
Current output pin. Connect to VSNS3 if not used. |
| PWM1 |
3 |
I |
PWM input and channel ON or OFF. Tie to GND if this channel is not used. |
| PWM2 |
4 |
I |
PWM input and channel ON or OFF. Tie to GND if this channel is not used. |
| PWM3 |
5 |
I |
PWM input and channel ON or OFF. Tie to GND if this channel is not used. |
| REF |
9 |
O |
Reference resistor pin for normal current setting |
| TEMP |
8 |
I/O |
Temperature foldback threshold program. Tie to GND if not used. |
| VIN |
1 |
— |
Input pin – VBAT supply |
| VSNS1 |
11 |
I |
String voltage sense. Connect to IOUT1 if not used. |
| VSNS2 |
12 |
I |
String voltage sense. Connect to IOUT2 if not used. |
| VSNS3 |
13 |
I |
String voltage sense. Connect to IOUT3 if not used. |
| Thermal pad |
— |
— |
Connect to GND |