All voltages are with respect to Vss(1)(2)
|
MIN |
MAX |
UNIT |
| VDD |
Supply voltage |
–0.3 |
20 |
V |
| VEN, VHI, VLI |
Input voltages on EN, HI and LI |
–0.3 |
20 |
V |
| VLO |
Output voltage on LO |
DC |
–0.3 |
VDD + 0.3 |
V |
| Pulses < 100ns(3) |
–2 |
VDD + 0.3 |
| VHO |
Output voltage on HO |
DC |
VHS – 0.3 |
VHB + 0.3 |
V |
| Pulses < 100ns(3) |
VHS – 2 |
VHB + 0.3 |
| VHS |
Voltage on HS |
DC |
–5 |
105 |
V |
| Pulses <
100ns(3) |
–7 |
105 |
| VHB |
Voltage on HB |
–0.3 |
110 |
V |
| VHB-HS |
Voltage on HB with respect to HS |
–0.3 |
20 |
V |
| TJ |
Operating junction temperature |
–40 |
150 |
°C |
|
Lead temperature (soldering, 10 sec.) |
|
300 |
°C |
| Tstg |
Storage temperature |
–65 |
150 |
°C |
(1) Operation outside the Absolute Maximum Ratings may cause
permanent device damage. Absolute Maximum Ratings do not imply functional
operation of the device at these or any other conditions beyond those listed
under Recommended Operating Conditions. If used outside the Recommended
Operating Conditions but within the Absolute Maximum Ratings, the device may not
be fully functional, and this may affect device reliability, functionality,
performance, and shorten the device lifetime.
(2) All voltages are with respect to Vss. Currents are
positive into, negative out of the specified terminal.
(3) Values are verified by characterization only.